SolarEdge official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

SolarEdge SE3800A-US (3.79 kW)

3.8 kW, 240 Vac, 1-phase Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.79 kW
CEC Weighted Eff.
98%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE3800A-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.79 kW · 98% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE3800A-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE3800A-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.79 kW (3,790 W)
Nominal DC Input (Pdco)3,864 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency98%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current9.7 A
Night Tare Loss2.24 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE3800A-US
Max Continuous AC Current15.8 A @ 240V
125% Continuous Duty Current19.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.17–5.12 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE3800A-US
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W9–12 panels4.0–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Engineering FAQ — SolarEdge SE3800A-US

What size circuit breaker does the SolarEdge SE3800A-US require under NEC 705.12?
At 3.79 kW continuous AC output on 240V (15.8A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SolarEdge SE3800A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.79 kW unit with 4.17 kW to 5.12 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

SE3000x (3.01 kW)SE3300x (3.251 kW)SE3800H-US (3.747 kW)NX3800T-US (3.84 kW)NX5000T-US (4.99 kW)SE5000x (4.99 kW)All SolarEdge Equipment →