SolarEdge official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolarEdge NX9600T-US (9.6 kW)

9.6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.6 kW
CEC Weighted Eff.
99%
MPPT / Max DC
370–450V / 450V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge NX9600T-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 370–450 Vdc 370V 450V MAX 450V PV DC INPUT ≤ 450V DC 9.6 kW · 99% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

SolarEdge NX9600T-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)NX9600T-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.6 kW (9,600 W)
Nominal DC Input (Pdco)9,720 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency99%
MPPT Operating Window370 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current24.6 A
Night Tare Loss5.9 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for NX9600T-US
Max Continuous AC Current40 A @ 240V
125% Continuous Duty Current50.0 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.56–12.96 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for NX9600T-US
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–24 panels10.4–13.2 kW DC

Engineering FAQ — SolarEdge NX9600T-US

What size circuit breaker does the SolarEdge NX9600T-US require under NEC 705.12?
At 9.6 kW continuous AC output on 240V (40A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge NX9600T-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.6 kW unit with 10.56 kW to 12.96 kW DC of solar modules without exceeding 450V cold Voc.

More SolarEdge Inverters

SE7600H-US (7.616 kW)NX7600T-US (7.68 kW)SE9600H-US (9.568 kW)SE10000A-US (9.94 kW)SE10000H-US (9.994 kW)NX10000T-US (10 kW)All SolarEdge Equipment →