SolarEdge official logoCEC-Listed · 240V ResidentialString

SolarEdge SE10000A-US (9.94 kW)

10 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.94 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE10000A-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.94 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE10000A-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE10000A-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)9.94 kW (9,940 W)
Nominal DC Input (Pdco)10,205 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current25.5 A
Night Tare Loss5.95 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE10000A-US
Max Continuous AC Current41.4 A @ 240V
125% Continuous Duty Current51.8 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.93–13.42 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE10000A-US
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–24 panels11.0–13.2 kW DC

Engineering FAQ — SolarEdge SE10000A-US

What size circuit breaker does the SolarEdge SE10000A-US require under NEC 705.12?
At 9.94 kW continuous AC output on 240V (41.4A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE10000A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.94 kW unit with 10.93 kW to 13.42 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

NX7600T-US (7.68 kW)SE9600H-US (9.568 kW)NX9600T-US (9.6 kW)SE10000H-US (9.994 kW)NX10000T-US (10 kW)SE11400A-US (11.39 kW)All SolarEdge Equipment →