SolarEdge SE10000H-US (9.994 kW)

10 kW, 240 Vac, 1-phase, HD-Wave technology Grid Support Utility Interactive Inverter, with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.994 kW
CEC Weighted Eff.
99%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE10000H-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.994 kW · 99% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE10000H-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE10000H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.994 kW (9,994 W)
Nominal DC Input (Pdco)10,145 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency99%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current25.7 A
Night Tare Loss6 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE10000H-US
Max Continuous AC Current41.6 A @ 240V
125% Continuous Duty Current52.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.99–13.49 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE10000H-US
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Engineering FAQ — SolarEdge SE10000H-US

What size circuit breaker does the SolarEdge SE10000H-US require under NEC 705.12?
At 9.994 kW continuous AC output on 240V (41.6A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE10000H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.994 kW unit with 10.99 kW to 13.49 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters