SolarEdge official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

SolarEdge SE7600A-US (7.625 kW)

7.6 kW, 240 Vac, 1-phase Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.625 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE7600A-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.625 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE7600A-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE7600A-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.625 kW (7,625 W)
Nominal DC Input (Pdco)7,840 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current19.6 A
Night Tare Loss2.16 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE7600A-US
Max Continuous AC Current31.8 A @ 240V
125% Continuous Duty Current39.8 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.39–10.29 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE7600A-US
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Engineering FAQ — SolarEdge SE7600A-US

What size circuit breaker does the SolarEdge SE7600A-US require under NEC 705.12?
At 7.625 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge SE7600A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.625 kW unit with 8.39 kW to 10.29 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

NX6000T-US (6 kW)SE6000H-US (6.046 kW)SE7600H-US (7.616 kW)NX7600T-US (7.68 kW)SE9600H-US (9.568 kW)NX9600T-US (9.6 kW)All SolarEdge Equipment →