SolarEdge SE7600A-US (7.625 kW)
7.6 kW, 240 Vac, 1-phase Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
7.625 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | SolarEdge |
|---|---|
| Model Number (MPN) | SE7600A-US |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 7.625 kW (7,625 W) |
| Nominal DC Input (Pdco) | 7,840 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 360 – 480 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 480 Vdc |
| Max DC Input Current | 19.6 A |
| Night Tare Loss | 2.16 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 31.8 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 39.8 A |
| Minimum Standard Breaker | 40 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (8.39–10.29 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 21–26 panels | 8.4–10.4 kW DC |
| 440W | 19–23 panels | 8.4–10.1 kW DC |
| 550W | 15–19 panels | 8.3–10.4 kW DC |
Engineering FAQ — SolarEdge SE7600A-US
What size circuit breaker does the SolarEdge SE7600A-US require under NEC 705.12?
At 7.625 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge SE7600A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.625 kW unit with 8.39 kW to 10.29 kW DC of solar modules without exceeding 480V cold Voc.