Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

6.3 kW LONGi + Solis + Battery Solar Kit (California)

High-Efficiency Value Hybrid Backup · California NEM 3.0 Starter. Reference Bill of Materials pairing 15× LONGi Solar LR5-54HABD-420M with 1× Solis (Ginlong) S6-EH1P5K-H-US and 1× Fortress Power DuraRack DC energy storage system-10.8P2.

System Size
6.3 kW DC / 5 kW AC
Est. Annual Yield
10,403 kWh
Est. Savings (CA)
$2,911/yr
Turnkey Cash Est.
$29,209Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (15×) LONGi Solar LR5-54HABD-… 6.30 kW DC STC DC 2. INVERTER (1×) Solis (Ginlong) S6-EH1P5K… 5.00 kW AC · 240V 30A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 30A Backfeed · CA Grid 4. HOME ENERGY STORAGE (1×) Fortress Power DuraRack DC ener… · 10.8 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 6.3 kW LONGi + Solis + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesLONGi SolarLR5-54HABD-420M15×6.3 kW DC (307 sq ft)Panel Specs →
InverterSolis (Ginlong)S6-EH1P5K-H-US1×5 kW AC · 1.26× DC/AC · 30A BreakerInverter Specs →
Energy StorageFortress PowerDuraRack DC energy storage system-10.8P21×10.8 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 6.3 kW DC / 5 kW AC array produces an estimated 10,403 kWh/year (~$2,911/yr gross bill offset, simple pre-incentive payback ~10.0 years at the $29,209 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 307 sq ft, with a 1.26× DC/AC ratio and a 30A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $29,209 estimate for this 6.3 kW California solar kit?
The $29,209 figure is a pre-incentive 2026 turnkey cash estimate covering 15× LONGi Solar LR5-54HABD-420M panels, 1× Solis (Ginlong) S6-EH1P5K-H-US, 1× Fortress Power DuraRack DC energy storage system-10.8P2 (10.8 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 6.3 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 5 kW continuous AC output, the inverter requires a 30A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 30A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

6.2 kW Qcells + Enphase + Battery Solar Kit (California)16.2 kW Qcells + Enphase + Battery Solar Kit (California)11.0 kW REC + Tesla + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)All 120 Kits →