Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

6.6 kW REC + SMA + Battery Solar Kit (California)

German-Engineered Hybrid + Modular LFP Backup · California NEM 3.0 Starter. Reference Bill of Materials pairing 15× REC Solar REC440AA Pure-RX-DC with 1× SMA Solar SBSE5.8-US-50 and 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5.

System Size
6.6 kW DC / 5.78 kW AC
Est. Annual Yield
10,898 kWh
Est. Savings (CA)
$2,253/yr
Turnkey Cash Est.
$27,520Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (15×) REC Solar REC440AA Pure… 6.60 kW DC STC DC 2. INVERTER (1×) SMA Solar SBSE5.8-US-50 5.78 kW AC · 240V 35A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 35A Backfeed · CA Grid 4. HOME ENERGY STORAGE (1×) SMA Solar SMA-ESS-SBS3.8-BYDH7.5 · 7.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 6.6 kW REC + SMA + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesREC SolarREC440AA Pure-RX-DC15×6.6 kW DC (326 sq ft)Panel Specs →
InverterSMA SolarSBSE5.8-US-501×5.78 kW AC · 1.14× DC/AC · 35A BreakerInverter Specs →
Energy StorageSMA SolarSMA-ESS-SBS3.8-BYDH7.51×7.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 6.6 kW DC / 5.78 kW AC array produces an estimated 10,898 kWh/year (~$2,253/yr gross bill offset, simple pre-incentive payback ~12.2 years at the $27,520 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 326 sq ft, with a 1.14× DC/AC ratio and a 35A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $27,520 estimate for this 6.6 kW California solar kit?
The $27,520 figure is a pre-incentive 2026 turnkey cash estimate covering 15× REC Solar REC440AA Pure-RX-DC panels, 1× SMA Solar SBSE5.8-US-50, 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5 (7.5 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 6.6 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 5.78 kW continuous AC output, the inverter requires a 35A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 35A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

6.2 kW Qcells + Enphase + Battery Solar Kit (California)16.2 kW Qcells + Enphase + Battery Solar Kit (California)11.0 kW REC + Tesla + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)All 120 Kits →