Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

6.2 kW Trina + Hoymiles + Battery Solar Kit (California)

Cost-Optimized Microinverter + Heavy LFP · California NEM 3.0 Starter. Reference Bill of Materials pairing 14× Trina Solar TSM-445NEG9RH.25 with 14× Hoymiles HMS-400-1A-NA and 1× Fortress Power eForce DC energy storage system-9.6P1-0.

System Size
6.23 kW DC / 5.07 kW AC
Est. Annual Yield
10,287 kWh
Est. Savings (CA)
$2,126/yr
Turnkey Cash Est.
$28,066Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (14×) Trina Solar TSM-445NEG9… 6.23 kW DC STC DC 2. INVERTER (14×) Hoymiles HMS-400-1A-NA 5.07 kW AC · 240V 30A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 30A Backfeed · CA Grid 4. HOME ENERGY STORAGE (1×) Fortress Power eForce DC energy… · 9.6 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 6.2 kW Trina + Hoymiles + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesTrina SolarTSM-445NEG9RH.2514×6.23 kW DC (298 sq ft)Panel Specs →
InverterHoymilesHMS-400-1A-NA14×5.07 kW AC · 1.23× DC/AC · 30A BreakerInverter Specs →
Energy StorageFortress PowereForce DC energy storage system-9.6P1-01×9.6 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 6.23 kW DC / 5.07 kW AC array produces an estimated 10,287 kWh/year (~$2,126/yr gross bill offset, simple pre-incentive payback ~13.2 years at the $28,066 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 298 sq ft, with a 1.23× DC/AC ratio and a 30A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $28,066 estimate for this 6.23 kW California solar kit?
The $28,066 figure is a pre-incentive 2026 turnkey cash estimate covering 14× Trina Solar TSM-445NEG9RH.25 panels, 14× Hoymiles HMS-400-1A-NA, 1× Fortress Power eForce DC energy storage system-9.6P1-0 (9.6 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 6.23 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 5.07 kW continuous AC output, the inverter requires a 30A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 30A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

6.2 kW Qcells + Enphase + Battery Solar Kit (California)16.2 kW Qcells + Enphase + Battery Solar Kit (California)11.0 kW REC + Tesla + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)All 120 Kits →