Energate Enerji Üretim San. A.Ş EG-144L530W
530 W, 144 half-cut cell monocrystalline module, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
530W / 496.5W
Efficiency
20.7%
Voc / Vmp
49.26V / 40.56V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Energate Enerji Üretim San. A.Ş |
|---|---|
| Model Number (MPN) | EG-144L530W |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 530 W |
| Real-World Output (PTC) | 496.5 W (93.7% of STC) |
| Module Efficiency | 20.7% (207 W/m²) |
| Open-Circuit Voltage (Voc) | 49.26 V |
| Maximum Power Voltage (Vmp) | 40.56 V |
| Short-Circuit Current (Isc) | 13.71 A (NEC 1.25× = 17.14 A) |
| Maximum Power Current (Imp) | 13.07 A |
| Temp. Coeff. Power (γPmax) | -0.355 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.306 %/°C |
| Temp. Coeff. Current (αIsc) | +0.055 %/°C |
| Nominal Cell Temp (NOCT) | 43.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.306%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.26 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.03 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.54 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.04 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.55 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.36 kW | 331 sq ft (30.7 m²) |
| 8 kW | 16 panels | 8.48 kW | 441 sq ft (41.0 m²) |
| 10 kW | 19 panels | 10.07 kW | 524 sq ft (48.6 m²) |
| 12 kW | 23 panels | 12.19 kW | 634 sq ft (58.9 m²) |
Compatible CEC-Listed Inverters for EG-144L530W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.38 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Energate Enerji Üretim San. A.Ş Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| EG-144L535W | 535 W | 501.3 W | 49.34 V | 13.79 A | 20.9% |
| EG-144L540W | 540 W | 506.1 W | 49.42 V | 13.85 A | 21.09% |
| EG-144L545W | 545 W | 510.9 W | 49.52 V | 13.94 A | 21.29% |
| EG-144L550W | 550 W | 515.8 W | 49.62 V | 14.03 A | 21.48% |
Engineering FAQ — Energate Enerji Üretim San. A.Ş EG-144L530W
How many Energate Enerji Üretim San. A.Ş EG-144L530W panels can fit in one 600V string?
At -10°C (14°F) ambient, the EG-144L530W open-circuit voltage rises from 49.26V to 54.54V (using βVoc -0.306%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Energate Enerji Üretim San. A.Ş EG-144L530W?
Rated at 530W STC, the EG-144L530W carries a 496.5W PTC rating (93.7% PTC/STC ratio) and 20.7% module efficiency across 2.56 m² (27.6 sq ft).
Is the Energate Enerji Üretim San. A.Ş EG-144L530W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.