G-Star GSD8K66T-730WT
730 W, 132 cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
730W / 695.5W
Efficiency
23.7%
Voc / Vmp
49.74V / 41.29V
Max String (600V)
11 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | G-Star |
|---|---|
| Model Number (MPN) | GSD8K66T-730WT |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 730 W |
| Real-World Output (PTC) | 695.5 W (95.3% of STC) |
| Module Efficiency | 23.7% (237 W/m²) |
| Open-Circuit Voltage (Voc) | 49.74 V |
| Maximum Power Voltage (Vmp) | 41.29 V |
| Short-Circuit Current (Isc) | 18.34 A (NEC 1.25× = 22.93 A) |
| Maximum Power Current (Imp) | 17.68 A |
| Temp. Coeff. Power (γPmax) | -0.29 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.235 %/°C |
| Temp. Coeff. Current (αIsc) | +0.042 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 3.08 m² (33.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.235%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.74 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.66 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.83 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.17 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 9 panels | 6.57 kW | 298 sq ft (27.7 m²) |
| 8 kW | 11 panels | 8.03 kW | 365 sq ft (33.9 m²) |
| 10 kW | 14 panels | 10.22 kW | 464 sq ft (43.1 m²) |
| 12 kW | 17 panels | 12.41 kW | 564 sq ft (52.4 m²) |
CEC-Listed US Equivalents to G-Star GSD8K66T-730WT
Looking to build a compliant US residential system with comparable wattage (730W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for GSD8K66T-730WT
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8P-72-2-US | Microinverter | 0.475 kW | 97.5% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Symo 10.0-3 208-240 | String | 9.995 kW | 96.5% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This G-Star Series (9 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GSD8K66T-700WT | 700 W | 666.3 W | 48.6 V | 18.1 A | 22.73% |
| GSD8K66T-705WT | 705 W | 671.1 W | 48.79 V | 18.14 A | 22.89% |
| GSD8K66T-710WT | 710 W | 676 W | 48.98 V | 18.18 A | 23.05% |
| GSD8K66T-715WT | 715 W | 680.9 W | 49.17 V | 18.22 A | 23.21% |
| GSD8K66T-720WT | 720 W | 685.7 W | 49.36 V | 18.26 A | 23.38% |
| GSD8K66T-725WT | 725 W | 690.6 W | 49.55 V | 18.3 A | 23.54% |
| GSD8K66T-735WT | 735 W | 700.4 W | 49.93 V | 18.38 A | 23.86% |
| GSD8K66T-740WT | 740 W | 705.2 W | 50.12 V | 18.42 A | 24.03% |
Engineering FAQ — G-Star GSD8K66T-730WT
How many G-Star GSD8K66T-730WT panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSD8K66T-730WT open-circuit voltage rises from 49.74V to 53.83V (using βVoc -0.235%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the G-Star GSD8K66T-730WT?
Rated at 730W STC, the GSD8K66T-730WT carries a 695.5W PTC rating (95.3% PTC/STC ratio) and 23.7% module efficiency across 3.08 m² (33.2 sq ft).
Is the G-Star GSD8K66T-730WT listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Residential (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.