Hansol Technics HA610ZB-GGFA0
610 W, 120 cell double glass monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
610W / 574.8W
Efficiency
21.71%
Voc / Vmp
42V / 35.1V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hansol Technics |
|---|---|
| Model Number (MPN) | HA610ZB-GGFA0 |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 610 W |
| Real-World Output (PTC) | 574.8 W (94.2% of STC) |
| Module Efficiency | 21.71% (217.1 W/m²) |
| Open-Circuit Voltage (Voc) | 42 V |
| Maximum Power Voltage (Vmp) | 35.1 V |
| Short-Circuit Current (Isc) | 18.48 A (NEC 1.25× = 23.10 A) |
| Maximum Power Current (Imp) | 17.38 A |
| Temp. Coeff. Power (γPmax) | -0.336 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.289 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.81 m² (30.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.289%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 42 V | 14 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 45.03 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 46.25 V | 12 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 47.46 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 48.68 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.10 kW | 302 sq ft (28.1 m²) |
| 8 kW | 14 panels | 8.54 kW | 423 sq ft (39.3 m²) |
| 10 kW | 17 panels | 10.37 kW | 514 sq ft (47.8 m²) |
| 12 kW | 20 panels | 12.20 kW | 605 sq ft (56.2 m²) |
Compatible CEC-Listed Inverters for HA610ZB-GGFA0
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems YC600 | Microinverter | 0.55 kW | 96.5% | 1:1 micro pairing (1.11 DC/AC ratio) | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ9N-A-DOM-US | Microinverter | 0.427 kW | 97.5% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Symo 10.0-3 208-240 | String | 9.995 kW | 96.5% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 5–10 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 5–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hansol Technics Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HA590ZB-GGFA0 | 590 W | 555.5 W | 41.2 V | 18.3 A | 21% |
| HA595ZB-GGFA0 | 595 W | 560.3 W | 41.4 V | 18.34 A | 21.17% |
| HA600ZB-GGFA0 | 600 W | 565.1 W | 41.6 V | 18.39 A | 21.35% |
| HA605ZB-GGFA0 | 605 W | 569.9 W | 41.8 V | 18.43 A | 21.53% |
Engineering FAQ — Hansol Technics HA610ZB-GGFA0
How many Hansol Technics HA610ZB-GGFA0 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HA610ZB-GGFA0 open-circuit voltage rises from 42V to 46.25V (using βVoc -0.289%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hansol Technics HA610ZB-GGFA0?
Rated at 610W STC, the HA610ZB-GGFA0 carries a 574.8W PTC rating (94.2% PTC/STC ratio) and 21.71% module efficiency across 2.81 m² (30.2 sq ft).
Is the Hansol Technics HA610ZB-GGFA0 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.