APsystems official logoCEC-Listed · 240V ResidentialMicroinverter

APsystems YC600 (0.55 kW)

548 W, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.55 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
24–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems YC600 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 24–45 Vdc 24V 45V MAX 45V PV DC INPUT ≤ 45V DC 0.55 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

APsystems YC600 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)YC600
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.55 kW (550 W)
Nominal DC Input (Pdco)570 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window24 – 45 Vdc (NREL SAM Measured)
Max DC Input Voltage45 Vdc
Max DC Input Current15.8 A
Night Tare Loss0.02 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for YC600
Max Continuous AC Current2.3 A @ 240V
125% Continuous Duty Current2.9 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.61–0.74 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for YC600
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.73× DC/AC)
440W1 panel1:1 pairing (0.80× DC/AC)
550W1 panel1:1 pairing (1.00× DC/AC)

Compatible Solar Panels for APsystems YC600

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for APsystems YC600
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.05 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.05 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.05 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.02 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.01 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 1.03 (1 panel/input)Verify Pair

Engineering FAQ — APsystems YC600

What size circuit breaker does the APsystems YC600 require under NEC 705.12?
At 0.55 kW continuous AC output on 240V (2.3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems YC600?
As a 550W microinverter, it pairs 1:1 with panels rated roughly 578W to 798W STC.

More APsystems Inverters

ELS-7.6 (7.609 kW)ELS-9.6 (9.606 kW)ELS-11.4 (11.415 kW)DS3-S (0.656 kW)DS3-L (0.78 kW)DS3 (0.896 kW)All APsystems Equipment →