635 W, 156 cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
635W / 604.2W
Efficiency
22.92%
Voc / Vmp
56V / 46.4V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hansol Technics |
|---|---|
| Model Number (MPN) | HA635AE-NGEA0 |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 635 W |
| Real-World Output (PTC) | 604.2 W (95.1% of STC) |
| Module Efficiency | 22.92% (229.2 W/m²) |
| Open-Circuit Voltage (Voc) | 56 V |
| Maximum Power Voltage (Vmp) | 46.4 V |
| Short-Circuit Current (Isc) | 14.43 A (NEC 1.25× = 18.04 A) |
| Maximum Power Current (Imp) | 13.68 A |
| Temp. Coeff. Power (γPmax) | -0.294 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.245 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.245%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 56 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 59.43 V | 10 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 60.8 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 62.17 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 63.55 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.35 kW | 298 sq ft (27.7 m²) |
| 8 kW | 13 panels | 8.26 kW | 388 sq ft (36.0 m²) |
| 10 kW | 16 panels | 10.16 kW | 477 sq ft (44.3 m²) |
| 12 kW | 19 panels | 12.06 kW | 567 sq ft (52.6 m²) |
Compatible CEC-Listed Inverters for HA635AE-NGEA0
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (0.99 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hansol Technics Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HA610AE-NGEA0 | 610 W | 579.9 W | 55.3 V | 14.03 A | 22.02% |
| HA615AE-NGEA0 | 615 W | 584.7 W | 55.4 V | 14.11 A | 22.2% |
| HA620AE-NGEA0 | 620 W | 589.6 W | 55.6 V | 14.19 A | 22.38% |
| HA625AE-NGEA0 | 625 W | 594.4 W | 55.7 V | 14.27 A | 22.56% |
| HA630AE-NGEA0 | 630 W | 599.3 W | 55.9 V | 14.35 A | 22.74% |
Engineering FAQ — Hansol Technics HA635AE-NGEA0
How many Hansol Technics HA635AE-NGEA0 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HA635AE-NGEA0 open-circuit voltage rises from 56V to 60.8V (using βVoc -0.245%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hansol Technics HA635AE-NGEA0?
Rated at 635W STC, the HA635AE-NGEA0 carries a 604.2W PTC rating (95.1% PTC/STC ratio) and 22.92% module efficiency across 2.77 m² (29.8 sq ft).
Is the Hansol Technics HA635AE-NGEA0 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.