Hyundai Energy HiS-S375YG
375 W, 120 half-cut cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
375W / 352W
Efficiency
20.6%
Voc / Vmp
41.8V / 34.8V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hyundai Energy |
|---|---|
| Model Number (MPN) | HiS-S375YG |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 375 W |
| Real-World Output (PTC) | 352 W (93.9% of STC) |
| Module Efficiency | 20.6% (206 W/m²) |
| Open-Circuit Voltage (Voc) | 41.8 V |
| Maximum Power Voltage (Vmp) | 34.8 V |
| Short-Circuit Current (Isc) | 11.42 A (NEC 1.25× = 14.28 A) |
| Maximum Power Current (Imp) | 10.78 A |
| Temp. Coeff. Power (γPmax) | -0.351 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.268 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.82 m² (19.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.268%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41.8 V | 14 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 44.6 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.72 V | 13 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 46.84 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.96 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.00 kW | 313 sq ft (29.1 m²) |
| 8 kW | 22 panels | 8.25 kW | 431 sq ft (40.0 m²) |
| 10 kW | 27 panels | 10.13 kW | 529 sq ft (49.1 m²) |
| 12 kW | 32 panels | 12.00 kW | 627 sq ft (58.2 m²) |
Compatible CEC-Listed Inverters for HiS-S375YG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.39 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hyundai Energy Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HiS-S350YG | 350 W | 328 W | 40.3 V | 11.06 A | 19.23% |
| HiS-S355YG | 355 W | 332.8 W | 40.6 V | 11.13 A | 19.51% |
| HiS-S360YG | 360 W | 337.6 W | 41 V | 11.2 A | 19.78% |
| HiS-S365YG | 365 W | 342.4 W | 41.3 V | 11.28 A | 20.05% |
| HiS-S370YG | 370 W | 347.2 W | 41.5 V | 11.35 A | 20.33% |
Engineering FAQ — Hyundai Energy HiS-S375YG
How many Hyundai Energy HiS-S375YG panels can fit in one 600V string?
At -10°C (14°F) ambient, the HiS-S375YG open-circuit voltage rises from 41.8V to 45.72V (using βVoc -0.268%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hyundai Energy HiS-S375YG?
Rated at 375W STC, the HiS-S375YG carries a 352W PTC rating (93.9% PTC/STC ratio) and 20.6% module efficiency across 1.82 m² (19.6 sq ft).
Is the Hyundai Energy HiS-S375YG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.