Hyundai Energy HiS-T645NJ
645W, 156 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
645W / 610.4W
Efficiency
23.37%
Voc / Vmp
57.97V / 47.9V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hyundai Energy |
|---|---|
| Model Number (MPN) | HiS-T645NJ |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 645 W |
| Real-World Output (PTC) | 610.4 W (94.6% of STC) |
| Module Efficiency | 23.37% (233.7 W/m²) |
| Open-Circuit Voltage (Voc) | 57.97 V |
| Maximum Power Voltage (Vmp) | 47.9 V |
| Short-Circuit Current (Isc) | 14.14 A (NEC 1.25× = 17.68 A) |
| Maximum Power Current (Imp) | 13.47 A |
| Temp. Coeff. Power (γPmax) | -0.294 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.233 %/°C |
| Temp. Coeff. Current (αIsc) | +0.03 %/°C |
| Nominal Cell Temp (NOCT) | 45.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.76 m² (29.7 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.233%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 57.97 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 61.35 V | 9 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 62.7 V | 9 | 15 |
| -20°C / -4°F Northeast / Midwest Winter | 64.05 V | 9 | 15 |
| -30°C / -22°F Northern Plains / Mountain | 65.4 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.45 kW | 297 sq ft (27.6 m²) |
| 8 kW | 13 panels | 8.38 kW | 386 sq ft (35.9 m²) |
| 10 kW | 16 panels | 10.32 kW | 475 sq ft (44.2 m²) |
| 12 kW | 19 panels | 12.26 kW | 564 sq ft (52.4 m²) |
Compatible CEC-Listed Inverters for HiS-T645NJ
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (1.01 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–12 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–7 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hyundai Energy Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HiS-T615NJ | 615 W | 581.4 W | 56.74 V | 13.67 A | 22.28% |
| HiS-T620NJ | 620 W | 586.2 W | 56.95 V | 13.75 A | 22.46% |
| HiS-T625NJ | 625 W | 591 W | 57.15 V | 13.82 A | 22.64% |
| HiS-T630NJ | 630 W | 595.9 W | 57.36 V | 13.9 A | 22.83% |
| HiS-T635NJ | 635 W | 600.7 W | 57.56 V | 13.98 A | 23.01% |
| HiS-T640NJ | 640 W | 605.6 W | 57.77 V | 14.06 A | 23.19% |
Engineering FAQ — Hyundai Energy HiS-T645NJ
How many Hyundai Energy HiS-T645NJ panels can fit in one 600V string?
At -10°C (14°F) ambient, the HiS-T645NJ open-circuit voltage rises from 57.97V to 62.7V (using βVoc -0.233%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hyundai Energy HiS-T645NJ?
Rated at 645W STC, the HiS-T645NJ carries a 610.4W PTC rating (94.6% PTC/STC ratio) and 23.37% module efficiency across 2.76 m² (29.7 sq ft).
Is the Hyundai Energy HiS-T645NJ listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.