JOLYWOOD (TAIZHOU) SOLAR JW-HD156N-R0-640
640 W, 156 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
640W / 605.7W
Efficiency
22.86%
Voc / Vmp
56.7V / 48.2V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | JOLYWOOD (TAIZHOU) SOLAR |
|---|---|
| Model Number (MPN) | JW-HD156N-R0-640 |
| Cell Technology | Mono-c-Si (Bifacial) · 156 cells |
| Nameplate Power (Pmax STC) | 640 W |
| Real-World Output (PTC) | 605.7 W (94.6% of STC) |
| Module Efficiency | 22.86% (228.6 W/m²) |
| Open-Circuit Voltage (Voc) | 56.7 V |
| Maximum Power Voltage (Vmp) | 48.2 V |
| Short-Circuit Current (Isc) | 13.94 A (NEC 1.25× = 17.43 A) |
| Maximum Power Current (Imp) | 13.3 A |
| Temp. Coeff. Power (γPmax) | -0.32 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.238 %/°C |
| Temp. Coeff. Current (αIsc) | +0.046 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.8 m² (30.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.238%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 56.7 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 60.07 V | 9 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 61.42 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 62.77 V | 9 | 15 |
| -30°C / -22°F Northern Plains / Mountain | 64.12 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.40 kW | 301 sq ft (28.0 m²) |
| 8 kW | 13 panels | 8.32 kW | 392 sq ft (36.4 m²) |
| 10 kW | 16 panels | 10.24 kW | 482 sq ft (44.8 m²) |
| 12 kW | 19 panels | 12.16 kW | 573 sq ft (53.2 m²) |
Compatible CEC-Listed Inverters for JW-HD156N-R0-640
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (1.00 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This JOLYWOOD (TAIZHOU) SOLAR Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JW-HD156N-R0-625 | 625 W | 591.2 W | 56.2 V | 13.79 A | 22.32% |
| JW-HD156N-R0-630 | 630 W | 596 W | 56.4 V | 13.84 A | 22.5% |
| JW-HD156N-R0-635 | 635 W | 600.9 W | 56.6 V | 13.89 A | 22.68% |
Engineering FAQ — JOLYWOOD (TAIZHOU) SOLAR JW-HD156N-R0-640
How many JOLYWOOD (TAIZHOU) SOLAR JW-HD156N-R0-640 panels can fit in one 600V string?
At -10°C (14°F) ambient, the JW-HD156N-R0-640 open-circuit voltage rises from 56.7V to 61.42V (using βVoc -0.238%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the JOLYWOOD (TAIZHOU) SOLAR JW-HD156N-R0-640?
Rated at 640W STC, the JW-HD156N-R0-640 carries a 605.7W PTC rating (94.6% PTC/STC ratio) and 22.86% module efficiency across 2.8 m² (30.1 sq ft).
Is the JOLYWOOD (TAIZHOU) SOLAR JW-HD156N-R0-640 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.