Lumos XL156 (630W)
630 W, 156 half-cut cell monocrystalline module, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
630W / 597.8W
Efficiency
22.74%
Voc / Vmp
57.1V / 49V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Lumos |
|---|---|
| Model Number (MPN) | XL156 |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 630 W |
| Real-World Output (PTC) | 597.8 W (94.9% of STC) |
| Module Efficiency | 22.74% (227.4 W/m²) |
| Open-Circuit Voltage (Voc) | 57.1 V |
| Maximum Power Voltage (Vmp) | 49 V |
| Short-Circuit Current (Isc) | 13.6 A (NEC 1.25× = 17.00 A) |
| Maximum Power Current (Imp) | 12.87 A |
| Temp. Coeff. Power (γPmax) | -0.305 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.198 %/°C |
| Temp. Coeff. Current (αIsc) | +0.014 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.198%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 57.1 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 59.93 V | 10 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 61.06 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 62.19 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 63.32 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.30 kW | 298 sq ft (27.7 m²) |
| 8 kW | 13 panels | 8.19 kW | 388 sq ft (36.0 m²) |
| 10 kW | 16 panels | 10.08 kW | 477 sq ft (44.3 m²) |
| 12 kW | 20 panels | 12.60 kW | 596 sq ft (55.4 m²) |
Compatible CEC-Listed Inverters for XL156
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 5–7 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (0.99 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Engineering FAQ — Lumos XL156
How many Lumos XL156 panels can fit in one 600V string?
At -10°C (14°F) ambient, the XL156 open-circuit voltage rises from 57.1V to 61.06V (using βVoc -0.198%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Lumos XL156?
Rated at 630W STC, the XL156 carries a 597.8W PTC rating (94.9% PTC/STC ratio) and 22.74% module efficiency across 2.77 m² (29.8 sq ft).
Is the Lumos XL156 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.