410 W, 72 cell double glass bifacial monocrystalline module, 1500V max system Vdc, where xx can be LC, RC, LM, RM, EM, PM, or IM. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
410W / 382W
Efficiency
17.98%
Voc / Vmp
48.8V / 39.6V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Lumos |
|---|---|
| Model Number (MPN) | L72-410-08-xx |
| Cell Technology | Mono-c-Si (Bifacial) · 72 cells |
| Nameplate Power (Pmax STC) | 410 W |
| Real-World Output (PTC) | 382 W (93.2% of STC) |
| Module Efficiency | 17.98% (179.8 W/m²) |
| Open-Circuit Voltage (Voc) | 48.8 V |
| Maximum Power Voltage (Vmp) | 39.6 V |
| Short-Circuit Current (Isc) | 10.9 A (NEC 1.25× = 13.63 A) |
| Maximum Power Current (Imp) | 10.38 A |
| Temp. Coeff. Power (γPmax) | -0.37 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.324 %/°C |
| Temp. Coeff. Current (αIsc) | +0.03 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.28 m² (24.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.324%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.8 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.75 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.33 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.92 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.5 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.15 kW | 368 sq ft (34.2 m²) |
| 8 kW | 20 panels | 8.20 kW | 491 sq ft (45.6 m²) |
| 10 kW | 25 panels | 10.25 kW | 614 sq ft (57.0 m²) |
| 12 kW | 30 panels | 12.30 kW | 736 sq ft (68.4 m²) |
Compatible CEC-Listed Inverters for L72-410-08-xx
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| Growatt SPH 4600TL BL-US | Hybrid | 4.598 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Lumos Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| L72-415-08-xx | 415 W | 386.7 W | 48.9 V | 11 A | 18.2% |
| L72-420-08-xx | 420 W | 391.5 W | 49 V | 11.1 A | 18.42% |
| L72-425-08-xx | 425 W | 396.3 W | 49.1 V | 11.2 A | 18.64% |
| L72-430-08-xx | 430 W | 401 W | 49.2 V | 11.3 A | 18.86% |
| L72-435-08-xx | 435 W | 405.8 W | 49.3 V | 11.4 A | 19.08% |
Engineering FAQ — Lumos L72-410-08-xx
How many Lumos L72-410-08-xx panels can fit in one 600V string?
At -10°C (14°F) ambient, the L72-410-08-xx open-circuit voltage rises from 48.8V to 54.33V (using βVoc -0.324%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Lumos L72-410-08-xx?
Rated at 410W STC, the L72-410-08-xx carries a 382W PTC rating (93.2% PTC/STC ratio) and 17.98% module efficiency across 2.28 m² (24.5 sq ft).
Is the Lumos L72-410-08-xx listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.