Lumos S60-340-13-IM
340 W, 60 cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
340W / 316.6W
Efficiency
17.62%
Voc / Vmp
40.7V / 32.64V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Lumos |
|---|---|
| Model Number (MPN) | S60-340-13-IM |
| Cell Technology | Mono-c-Si (Bifacial) · 60 cells |
| Nameplate Power (Pmax STC) | 340 W |
| Real-World Output (PTC) | 316.6 W (93.1% of STC) |
| Module Efficiency | 17.62% (176.2 W/m²) |
| Open-Circuit Voltage (Voc) | 40.7 V |
| Maximum Power Voltage (Vmp) | 32.64 V |
| Short-Circuit Current (Isc) | 11.1 A (NEC 1.25× = 13.88 A) |
| Maximum Power Current (Imp) | 10.48 A |
| Temp. Coeff. Power (γPmax) | -0.37 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.324 %/°C |
| Temp. Coeff. Current (αIsc) | +0.03 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.93 m² (20.8 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.324%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 40.7 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 44 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.32 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 46.63 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.95 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 18 panels | 6.12 kW | 374 sq ft (34.7 m²) |
| 8 kW | 24 panels | 8.16 kW | 499 sq ft (46.3 m²) |
| 10 kW | 30 panels | 10.20 kW | 623 sq ft (57.9 m²) |
| 12 kW | 36 panels | 12.24 kW | 748 sq ft (69.5 m²) |
Compatible CEC-Listed Inverters for S60-340-13-IM
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.26 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Lumos Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| S60-345-13-IM | 345 W | 321.4 W | 40.8 V | 11.2 A | 17.88% |
| S60-350-13-IM | 350 W | 326.1 W | 40.9 V | 11.3 A | 18.13% |
| S60-355-13-IM | 355 W | 330.9 W | 41 V | 11.4 A | 18.39% |
Engineering FAQ — Lumos S60-340-13-IM
How many Lumos S60-340-13-IM panels can fit in one 600V string?
At -10°C (14°F) ambient, the S60-340-13-IM open-circuit voltage rises from 40.7V to 45.32V (using βVoc -0.324%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Lumos S60-340-13-IM?
Rated at 340W STC, the S60-340-13-IM carries a 316.6W PTC rating (93.1% PTC/STC ratio) and 17.62% module efficiency across 1.93 m² (20.8 sq ft).
Is the Lumos S60-340-13-IM listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.