Philadelphia Solar PS-M156(HC)-605W
605 W, 156 half-cut cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
605W / 566.1W
Efficiency
21.84%
Voc / Vmp
55.49V / 45.98V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Philadelphia Solar |
|---|---|
| Model Number (MPN) | PS-M156(HC)-605W |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 605 W |
| Real-World Output (PTC) | 566.1 W (93.6% of STC) |
| Module Efficiency | 21.84% (218.4 W/m²) |
| Open-Circuit Voltage (Voc) | 55.49 V |
| Maximum Power Voltage (Vmp) | 45.98 V |
| Short-Circuit Current (Isc) | 13.87 A (NEC 1.25× = 17.34 A) |
| Maximum Power Current (Imp) | 13.17 A |
| Temp. Coeff. Power (γPmax) | -0.343 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.257 %/°C |
| Temp. Coeff. Current (αIsc) | +0.048 %/°C |
| Nominal Cell Temp (NOCT) | 45.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.257%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 55.49 V | 10 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 59.06 V | 10 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 60.48 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 61.91 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 63.33 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.05 kW | 298 sq ft (27.7 m²) |
| 8 kW | 14 panels | 8.47 kW | 417 sq ft (38.8 m²) |
| 10 kW | 17 panels | 10.29 kW | 507 sq ft (47.1 m²) |
| 12 kW | 20 panels | 12.10 kW | 596 sq ft (55.4 m²) |
Compatible CEC-Listed Inverters for PS-M156(HC)-605W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Philadelphia Solar Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| PS-M156(HC)-570W | 570 W | 532.5 W | 53.74 V | 13.52 A | 20.58% |
| PS-M156(HC)-575W | 575 W | 537.3 W | 53.99 V | 13.57 A | 20.76% |
| PS-M156(HC)-580W | 580 W | 542 W | 54.24 V | 13.62 A | 20.94% |
| PS-M156(HC)-585W | 585 W | 546.8 W | 54.49 V | 13.67 A | 21.12% |
| PS-M156(HC)-590W | 590 W | 551.6 W | 54.74 V | 13.72 A | 21.3% |
| PS-M156(HC)-595W | 595 W | 556.5 W | 54.99 V | 13.77 A | 21.48% |
| PS-M156(HC)-600W | 600 W | 561.3 W | 55.24 V | 13.82 A | 21.66% |
Engineering FAQ — Philadelphia Solar PS-M156(HC)-605W
How many Philadelphia Solar PS-M156(HC)-605W panels can fit in one 600V string?
At -10°C (14°F) ambient, the PS-M156(HC)-605W open-circuit voltage rises from 55.49V to 60.48V (using βVoc -0.257%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Philadelphia Solar PS-M156(HC)-605W?
Rated at 605W STC, the PS-M156(HC)-605W carries a 566.1W PTC rating (93.6% PTC/STC ratio) and 21.84% module efficiency across 2.77 m² (29.8 sq ft).
Is the Philadelphia Solar PS-M156(HC)-605W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.