PT IDN SOLAR TECH IDN156H-610ND
610 W, 156 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
610W / 578.6W
Efficiency
21.79%
Voc / Vmp
56.5V / 46.72V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT IDN SOLAR TECH |
|---|---|
| Model Number (MPN) | IDN156H-610ND |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 610 W |
| Real-World Output (PTC) | 578.6 W (94.9% of STC) |
| Module Efficiency | 21.79% (217.9 W/m²) |
| Open-Circuit Voltage (Voc) | 56.5 V |
| Maximum Power Voltage (Vmp) | 46.72 V |
| Short-Circuit Current (Isc) | 13.81 A (NEC 1.25× = 17.26 A) |
| Maximum Power Current (Imp) | 13.06 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.8 m² (30.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 56.5 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 59.89 V | 10 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 61.25 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 62.6 V | 9 | 15 |
| -30°C / -22°F Northern Plains / Mountain | 63.96 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.10 kW | 301 sq ft (28.0 m²) |
| 8 kW | 14 panels | 8.54 kW | 422 sq ft (39.2 m²) |
| 10 kW | 17 panels | 10.37 kW | 512 sq ft (47.6 m²) |
| 12 kW | 20 panels | 12.20 kW | 603 sq ft (56.0 m²) |
Compatible CEC-Listed Inverters for IDN156H-610ND
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (0.95 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This PT IDN SOLAR TECH Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| IDN156H-615ND | 615 W | 583.4 W | 56.7 V | 13.87 A | 21.96% |
| IDN156H-620ND | 620 W | 588.3 W | 56.9 V | 13.93 A | 22.14% |
| IDN156H-625ND | 625 W | 593.1 W | 57.1 V | 13.99 A | 22.32% |
| IDN156H-630ND | 630 W | 598 W | 57.3 V | 14.04 A | 22.5% |
| IDN156H-635ND | 635 W | 602.8 W | 57.5 V | 14.1 A | 22.68% |
| IDN156H-640ND | 640 W | 607.7 W | 57.7 V | 14.15 A | 22.86% |
| IDN156H-645ND | 645 W | 612.5 W | 57.9 V | 14.2 A | 23.04% |
Engineering FAQ — PT IDN SOLAR TECH IDN156H-610ND
How many PT IDN SOLAR TECH IDN156H-610ND panels can fit in one 600V string?
At -10°C (14°F) ambient, the IDN156H-610ND open-circuit voltage rises from 56.5V to 61.25V (using βVoc -0.24%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT IDN SOLAR TECH IDN156H-610ND?
Rated at 610W STC, the IDN156H-610ND carries a 578.6W PTC rating (94.9% PTC/STC ratio) and 21.79% module efficiency across 2.8 m² (30.1 sq ft).
Is the PT IDN SOLAR TECH IDN156H-610ND listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.