Waaree Energies BiN-17-615
615 W, 156 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
615W / 582W
Efficiency
22.2%
Voc / Vmp
56.55V / 47.27V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Waaree Energies |
|---|---|
| Model Number (MPN) | BiN-17-615 |
| Cell Technology | Mono-c-Si (Bifacial) · 156 cells |
| Nameplate Power (Pmax STC) | 615 W |
| Real-World Output (PTC) | 582 W (94.6% of STC) |
| Module Efficiency | 22.2% (222 W/m²) |
| Open-Circuit Voltage (Voc) | 56.55 V |
| Maximum Power Voltage (Vmp) | 47.27 V |
| Short-Circuit Current (Isc) | 13.78 A (NEC 1.25× = 17.22 A) |
| Maximum Power Current (Imp) | 13.01 A |
| Temp. Coeff. Power (γPmax) | -0.308 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.245 %/°C |
| Temp. Coeff. Current (αIsc) | +0.033 %/°C |
| Nominal Cell Temp (NOCT) | 43.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.245%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 56.55 V | 10 | 17 |
| 0°C / 32°F Freezing / Mild Winter | 60.01 V | 9 | 16 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 61.4 V | 9 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 62.78 V | 9 | 15 |
| -30°C / -22°F Northern Plains / Mountain | 64.17 V | 9 | 15 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.15 kW | 298 sq ft (27.7 m²) |
| 8 kW | 14 panels | 8.61 kW | 417 sq ft (38.8 m²) |
| 10 kW | 17 panels | 10.46 kW | 507 sq ft (47.1 m²) |
| 12 kW | 20 panels | 12.30 kW | 596 sq ft (55.4 m²) |
Compatible CEC-Listed Inverters for BiN-17-615
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8D-BAT | Microinverter | 0.639 kW | 97% | 1:1 micro pairing (0.96 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–7 panels/string at -10°C | Verify Pair |
| Growatt MIN 7600TL-XH2 US | Hybrid | 7.651 kW | 96% | 4–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Waaree Energies Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| BiN-17-620 | 620 W | 586.8 W | 56.71 V | 13.83 A | 22.38% |
| BiN-17-625 | 625 W | 591.7 W | 56.88 V | 13.88 A | 22.56% |
| BiN-17-630 | 630 W | 596.5 W | 57.02 V | 13.94 A | 22.74% |
| BiN-17-635 | 635 W | 601.4 W | 57.18 V | 13.99 A | 22.92% |
| BiN-17-640 | 640 W | 606.2 W | 57.33 V | 14.05 A | 23.1% |
| BiN-17-645 | 645 W | 611.1 W | 57.49 V | 14.11 A | 23.29% |
Engineering FAQ — Waaree Energies BiN-17-615
How many Waaree Energies BiN-17-615 panels can fit in one 600V string?
At -10°C (14°F) ambient, the BiN-17-615 open-circuit voltage rises from 56.55V to 61.4V (using βVoc -0.245%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Waaree Energies BiN-17-615?
Rated at 615W STC, the BiN-17-615 carries a 582W PTC rating (94.6% PTC/STC ratio) and 22.2% module efficiency across 2.77 m² (29.8 sq ft).
Is the Waaree Energies BiN-17-615 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.