APsystems DS3-H (1.068 kW)
1050 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1.068 kW
CEC Weighted Eff.
97%
MPPT / Max DC
36–43V / 43V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | APsystems |
|---|---|
| Model Number (MPN) | DS3-H |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 1.068 kW (1,068 W) |
| Nominal DC Input (Pdco) | 1,104 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 36 – 43 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 43 Vdc |
| Max DC Input Current | 28.3 A |
| Night Tare Loss | 0.03 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 4.5 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 5.6 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1.17–1.44 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.37× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.41× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.51× DC/AC) |
Engineering FAQ — APsystems DS3-H
What size circuit breaker does the APsystems DS3-H require under NEC 705.12?
At 1.068 kW continuous AC output on 240V (4.5A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems DS3-H?
As a 1068W microinverter, it pairs 1:1 with panels rated roughly 1121W to 1549W STC.