APsystems official logoCEC-Listed · 240V ResidentialMicroinverter

APsystems QS1 (1.225 kW)

1.2 kW, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.225 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
27–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems QS1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–48 Vdc 27V 48V MAX 48V PV DC INPUT ≤ 48V DC 1.225 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

APsystems QS1 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)QS1
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.225 kW (1,225 W)
Nominal DC Input (Pdco)1,276 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window27 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current34 A
Night Tare Loss0.09 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for QS1
Max Continuous AC Current5.1 A @ 240V
125% Continuous Duty Current6.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.35–1.65 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for QS1
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.33× DC/AC)
440W1 panel1:1 pairing (0.36× DC/AC)
550W1 panel1:1 pairing (0.45× DC/AC)

Engineering FAQ — APsystems QS1

What size circuit breaker does the APsystems QS1 require under NEC 705.12?
At 1.225 kW continuous AC output on 240V (5.1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems QS1?
As a 1225W microinverter, it pairs 1:1 with panels rated roughly 1286W to 1776W STC.

More APsystems Inverters

DS3-L (0.78 kW)DS3 (0.896 kW)DS3-H (1.068 kW)QS1A (1.516 kW)QS2 (1.924 kW)ELS-3K (3.685 kW)All APsystems Equipment →