APsystems official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

APsystems QS2 (1.924 kW)

1920 VA, 240 Vac, Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.924 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
30–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems QS2 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 30–45 Vdc 30V 45V MAX 45V PV DC INPUT ≤ 45V DC 1.924 kW · 95.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

APsystems QS2 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)QS2
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.924 kW (1,924 W)
Nominal DC Input (Pdco)2,020 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency95.5%
MPPT Operating Window30 – 45 Vdc (NREL SAM Measured)
Max DC Input Voltage45 Vdc
Max DC Input Current53.2 A
Night Tare LossNot reported in CEC
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for QS2
Max Continuous AC Current8 A @ 240V
125% Continuous Duty Current10.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (2.12–2.6 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for QS2
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.21× DC/AC)
440W1 panel1:1 pairing (0.23× DC/AC)
550W1 panel1:1 pairing (0.29× DC/AC)

Engineering FAQ — APsystems QS2

What size circuit breaker does the APsystems QS2 require under NEC 705.12?
At 1.924 kW continuous AC output on 240V (8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems QS2?
As a 1924W microinverter, it pairs 1:1 with panels rated roughly 2020W to 2790W STC.

More APsystems Inverters