APsystems official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

APsystems DS3 (0.896 kW)

880 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.896 kW
CEC Weighted Eff.
97%
MPPT / Max DC
36–43V / 43V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems DS3 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 36–43 Vdc 36V 43V MAX 43V PV DC INPUT ≤ 43V DC 0.896 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

APsystems DS3 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)DS3
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.896 kW (896 W)
Nominal DC Input (Pdco)924 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window36 – 43 Vdc (NREL SAM Measured)
Max DC Input Voltage43 Vdc
Max DC Input Current23.7 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for DS3
Max Continuous AC Current3.7 A @ 240V
125% Continuous Duty Current4.6 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.99–1.21 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for DS3
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.45× DC/AC)
440W1 panel1:1 pairing (0.49× DC/AC)
550W1 panel1:1 pairing (0.61× DC/AC)

Engineering FAQ — APsystems DS3

What size circuit breaker does the APsystems DS3 require under NEC 705.12?
At 0.896 kW continuous AC output on 240V (3.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems DS3?
As a 896W microinverter, it pairs 1:1 with panels rated roughly 941W to 1299W STC.

More APsystems Inverters

YC600 (0.55 kW)DS3-S (0.656 kW)DS3-L (0.78 kW)DS3-H (1.068 kW)QS1 (1.225 kW)QS1A (1.516 kW)All APsystems Equipment →