APsystems official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

APsystems ELS-9.6 (9.606 kW)

ELS-9.6:9.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-9.6:8.3kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.606 kW
CEC Weighted Eff.
94%
MPPT / Max DC
51–500V / 600V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems ELS-9.6 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 51–500 Vdc 51V 500V MAX 600V PV DC INPUT ≤ 600V DC 9.606 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

APsystems ELS-9.6 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)ELS-9.6
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.606 kW (9,606 W)
Nominal DC Input (Pdco)10,246 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency94%
MPPT Operating Window51 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current183 A
Night Tare Loss11.04 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ELS-9.6
Max Continuous AC Current40 A @ 240V
125% Continuous Duty Current50.0 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.57–12.97 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ELS-9.6
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for APsystems ELS-9.6

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for APsystems ELS-9.6
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V2–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V2–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V2–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–8 per string (-10°C)Verify Pair

Engineering FAQ — APsystems ELS-9.6

What size circuit breaker does the APsystems ELS-9.6 require under NEC 705.12?
At 9.606 kW continuous AC output on 240V (40A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the APsystems ELS-9.6?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.606 kW unit with 10.57 kW to 12.97 kW DC of solar modules without exceeding 600V cold Voc.

More APsystems Inverters

ELS-3K (3.685 kW)ELS-5K (5.008 kW)ELS-7.6 (7.609 kW)ELS-11.4 (11.415 kW)YC600 (0.55 kW)DS3-S (0.656 kW)All APsystems Equipment →