APsystems official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

APsystems ELS-5K (5.008 kW)

5 kVA, 240 Vac, Grid Support Utility Interactive Bi-directional Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.008 kW
CEC Weighted Eff.
94%
MPPT / Max DC
52–500V / 600V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems ELS-5K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 52–500 Vdc 52V 500V MAX 600V PV DC INPUT ≤ 600V DC 5.008 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

APsystems ELS-5K Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)ELS-5K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.008 kW (5,008 W)
Nominal DC Input (Pdco)5,373 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window52 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current95.9 A
Night Tare Loss4.01 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ELS-5K
Max Continuous AC Current20.9 A @ 240V
125% Continuous Duty Current26.1 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.51–6.76 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ELS-5K
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for APsystems ELS-5K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for APsystems ELS-5K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V2–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V2–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V2–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–8 per string (-10°C)Verify Pair

Engineering FAQ — APsystems ELS-5K

What size circuit breaker does the APsystems ELS-5K require under NEC 705.12?
At 5.008 kW continuous AC output on 240V (20.9A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the APsystems ELS-5K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.008 kW unit with 5.51 kW to 6.76 kW DC of solar modules without exceeding 600V cold Voc.

More APsystems Inverters

QS1A (1.516 kW)QS2 (1.924 kW)ELS-3K (3.685 kW)ELS-7.6 (7.609 kW)ELS-9.6 (9.606 kW)ELS-11.4 (11.415 kW)All APsystems Equipment →