APsystems official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

APsystems ELS-7.6 (7.609 kW)

ELS-7.6:7.6kVA,240 Vac Grid Support Utility Interactive Bi-directional Battery Inverter with PCS functionality. ELS-7.6:6.6kVA,208 Vac Grid Support Utility Interactive Bi-directional Battery Inverte. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.609 kW
CEC Weighted Eff.
94%
MPPT / Max DC
51–500V / 600V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems ELS-7.6 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 51–500 Vdc 51V 500V MAX 600V PV DC INPUT ≤ 600V DC 7.609 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

APsystems ELS-7.6 Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)ELS-7.6
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.609 kW (7,609 W)
Nominal DC Input (Pdco)8,068 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency94%
MPPT Operating Window51 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current144.1 A
Night Tare Loss11.06 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for ELS-7.6
Max Continuous AC Current31.7 A @ 240V
125% Continuous Duty Current39.6 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.37–10.27 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for ELS-7.6
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for APsystems ELS-7.6

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for APsystems ELS-7.6
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V2–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V2–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V2–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V2–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V2–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V2–8 per string (-10°C)Verify Pair

Engineering FAQ — APsystems ELS-7.6

What size circuit breaker does the APsystems ELS-7.6 require under NEC 705.12?
At 7.609 kW continuous AC output on 240V (31.7A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the APsystems ELS-7.6?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.609 kW unit with 8.37 kW to 10.27 kW DC of solar modules without exceeding 600V cold Voc.

More APsystems Inverters

QS2 (1.924 kW)ELS-3K (3.685 kW)ELS-5K (5.008 kW)ELS-9.6 (9.606 kW)ELS-11.4 (11.415 kW)YC600 (0.55 kW)All APsystems Equipment →