FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fortress Power FP-ENVY-12K (11.933 kW)

12 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.933 kW
CEC Weighted Eff.
97%
MPPT / Max DC
230–480V / 480V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power FP-ENVY-12K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 230–480 Vdc 230V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.933 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Fortress Power FP-ENVY-12K Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)FP-ENVY-12K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.933 kW (11,933 W)
Nominal DC Input (Pdco)12,343 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window230 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current34.3 A
Night Tare Loss14.29 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for FP-ENVY-12K
Max Continuous AC Current49.7 A @ 240V
125% Continuous Duty Current62.1 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.13–16.11 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for FP-ENVY-12K
Panel ClassRecommended QtyDC Array / Ratio
400W33–40 panels13.2–16.0 kW DC
440W30–37 panels13.2–16.3 kW DC
550W24–29 panels13.2–15.9 kW DC

Compatible Solar Panels for Fortress Power FP-ENVY-12K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fortress Power FP-ENVY-12K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power FP-ENVY-12K

What size circuit breaker does the Fortress Power FP-ENVY-12K require under NEC 705.12?
At 11.933 kW continuous AC output on 240V (49.7A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fortress Power FP-ENVY-12K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.933 kW unit with 13.13 kW to 16.11 kW DC of solar modules without exceeding 480V cold Voc.

More Fortress Power Inverters

EdgeOn Duo 15 Lite (10.147 kW)Avalon HV PC114 (11.406 kW)EdgeOn Duo 15 Pro (11.567 kW)FP-Envy 15K (16.153 kW)Avalon HV PC50 (5.002 kW)EdgeOn Duo 7.5 (5.04 kW)All Fortress Power Equipment →