GN CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Generac APKE00075 (11.473 kW)

11.5 kW, 240 Vac, 1-phase Grid Support Utility Interactive Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.473 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
360–420V / 420V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Generac APKE00075 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–420 Vdc 360V 420V MAX 420V PV DC INPUT ≤ 420V DC 11.473 kW · 98.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Generac APKE00075 Electrical and Grid-Support Specifications
ManufacturerGenerac
Model Number (MPN)APKE00075
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.473 kW (11,473 W)
Nominal DC Input (Pdco)11,716 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency98.5%
MPPT Operating Window360 – 420 Vdc (NREL SAM Measured)
Max DC Input Voltage420 Vdc
Max DC Input Current29.3 A
Night Tare Loss77.44 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryTUV Rheinland of North America
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for APKE00075
Max Continuous AC Current47.8 A @ 240V
125% Continuous Duty Current59.8 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.62–15.49 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for APKE00075
Panel ClassRecommended QtyDC Array / Ratio
400W32–39 panels12.8–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Engineering FAQ — Generac APKE00075

What size circuit breaker does the Generac APKE00075 require under NEC 705.12?
At 11.473 kW continuous AC output on 240V (47.8A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Generac APKE00075?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.473 kW unit with 12.62 kW to 15.49 kW DC of solar modules without exceeding 420V cold Voc.

More Generac Inverters

PM-820 (0.82 kW)X7602 (7.586 kW)XVT076A03 (7.606 kW)CP-380-V2 (0.38 kW)CP-760-V2 (0.761 kW)All Generac Equipment →