GN CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Generac CP-380-V2 (0.38 kW)

380 W, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.38 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
32–36V / 36V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Generac CP-380-V2 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 32–36 Vdc 32V 36V MAX 36V PV DC INPUT ≤ 36V DC 0.38 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Generac CP-380-V2 Electrical and Grid-Support Specifications
ManufacturerGenerac
Model Number (MPN)CP-380-V2
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.38 kW (380 W)
Nominal DC Input (Pdco)392 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window32 – 36 Vdc (NREL SAM Measured)
Max DC Input Voltage36 Vdc
Max DC Input Current11.5 A
Night Tare Loss0.19 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CP-380-V2
Max Continuous AC Current1.6 A @ 240V
125% Continuous Duty Current2.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.42–0.51 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CP-380-V2
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.05× DC/AC)
440W1 panel1:1 pairing (1.16× DC/AC)
550W1 panel1:1 pairing (1.45× DC/AC)

Compatible Solar Panels for Generac CP-380-V2

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Generac CP-380-V2
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 1.53 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 1.53 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 1.51 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 1.47 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 1.46 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.25 (1 panel/input)Verify Pair

Engineering FAQ — Generac CP-380-V2

What size circuit breaker does the Generac CP-380-V2 require under NEC 705.12?
At 0.38 kW continuous AC output on 240V (1.6A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Generac CP-380-V2?
As a 380W microinverter, it pairs 1:1 with panels rated roughly 399W to 551W STC.