GN CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Generac CP-760-V2 (0.761 kW)

760 W, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.761 kW
CEC Weighted Eff.
97%
MPPT / Max DC
63–72V / 72V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Generac CP-760-V2 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 63–72 Vdc 63V 72V MAX 72V PV DC INPUT ≤ 72V DC 0.761 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Generac CP-760-V2 Electrical and Grid-Support Specifications
ManufacturerGenerac
Model Number (MPN)CP-760-V2
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.761 kW (761 W)
Nominal DC Input (Pdco)786 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency97%
MPPT Operating Window63 – 72 Vdc (NREL SAM Measured)
Max DC Input Voltage72 Vdc
Max DC Input Current11.6 A
Night Tare Loss0.19 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CP-760-V2
Max Continuous AC Current3.2 A @ 240V
125% Continuous Duty Current4.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.84–1.03 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CP-760-V2
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.53× DC/AC)
440W1 panel1:1 pairing (0.58× DC/AC)
550W1 panel1:1 pairing (0.72× DC/AC)

Engineering FAQ — Generac CP-760-V2

What size circuit breaker does the Generac CP-760-V2 require under NEC 705.12?
At 0.761 kW continuous AC output on 240V (3.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Generac CP-760-V2?
As a 761W microinverter, it pairs 1:1 with panels rated roughly 799W to 1103W STC.

More Generac Inverters

XVT076A03 (7.606 kW)APKE00075 (11.473 kW)CP-380-V2 (0.38 kW)PM-820 (0.82 kW)X7602 (7.586 kW)All Generac Equipment →