GN CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Generac PM-820 (0.82 kW)

0.82 kW, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.82 kW
CEC Weighted Eff.
97%
MPPT / Max DC
32–40V / 40V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Generac PM-820 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 32–40 Vdc 32V 40V MAX 40V PV DC INPUT ≤ 40V DC 0.82 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Generac PM-820 Electrical and Grid-Support Specifications
ManufacturerGenerac
Model Number (MPN)PM-820
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.82 kW (820 W)
Nominal DC Input (Pdco)847 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window32 – 40 Vdc (NREL SAM Measured)
Max DC Input Voltage40 Vdc
Max DC Input Current22.6 A
Night Tare Loss0.39 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PM-820
Max Continuous AC Current3.4 A @ 240V
125% Continuous Duty Current4.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.9–1.11 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PM-820
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.49× DC/AC)
440W1 panel1:1 pairing (0.54× DC/AC)
550W1 panel1:1 pairing (0.67× DC/AC)

Engineering FAQ — Generac PM-820

What size circuit breaker does the Generac PM-820 require under NEC 705.12?
At 0.82 kW continuous AC output on 240V (3.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Generac PM-820?
As a 820W microinverter, it pairs 1:1 with panels rated roughly 861W to 1189W STC.

More Generac Inverters

APKE00075 (11.473 kW)CP-380-V2 (0.38 kW)CP-760-V2 (0.761 kW)X7602 (7.586 kW)XVT076A03 (7.606 kW)All Generac Equipment →