GN CEC-Listed · 240V ResidentialHybridBattery Hybrid

Generac X7602 (7.586 kW)

7.6 kW, 240 Vac Grid Support Utility Interactive Inverter with PCS Functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.586 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
390–420V / 420V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Generac X7602 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 390–420 Vdc 390V 420V MAX 420V PV DC INPUT ≤ 420V DC 7.586 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Generac X7602 Electrical and Grid-Support Specifications
ManufacturerGenerac
Model Number (MPN)X7602
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.586 kW (7,586 W)
Nominal DC Input (Pdco)7,823 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window390 – 420 Vdc (NREL SAM Measured)
Max DC Input Voltage420 Vdc
Max DC Input Current19.6 A
Night Tare Loss1.29 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for X7602
Max Continuous AC Current31.6 A @ 240V
125% Continuous Duty Current39.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.34–10.24 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for X7602
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Engineering FAQ — Generac X7602

What size circuit breaker does the Generac X7602 require under NEC 705.12?
At 7.586 kW continuous AC output on 240V (31.6A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Generac X7602?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.586 kW unit with 8.34 kW to 10.24 kW DC of solar modules without exceeding 420V cold Voc.

More Generac Inverters

CP-380-V2 (0.38 kW)CP-760-V2 (0.761 kW)PM-820 (0.82 kW)XVT076A03 (7.606 kW)APKE00075 (11.473 kW)All Generac Equipment →