KACO new energy (Siemens) official logoCEC-Listed · Commercial / C&ICommercial 3-Phase

KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX (109.765 kW)

110 kVA, 480 Vac, 1500Vdc Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
109.765 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
705–1300V / 1300V
NEC 705.12 Breaker
175A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 705–1300 Vdc 705V 1300V MAX 1300V PV DC INPUT ≤ 1300V DC 109.765 kW · 98.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 480V · 175A BRKR

Electrical & Grid-Support Datasheet

KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX Electrical and Grid-Support Specifications
ManufacturerKACO new energy (Siemens)
Model Number (MPN)blueplanet 110 TL3 M1 WM OD IIKX
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)109.765 kW (109,765 W)
Nominal DC Input (Pdco)111,509 W
Nominal AC Voltage480 Vac (3-Phase)
CEC Weighted Efficiency98.5%
MPPT Operating Window705 – 1300 Vdc (NREL SAM Measured)
Max DC Input Voltage1300 Vdc
Max DC Input Current130.6 A
Night Tare Loss5 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for blueplanet 110 TL3 M1 WM OD IIKX
Max Continuous AC Current132 A @ 480V
125% Continuous Duty Current165.0 A
Minimum Standard Breaker175 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (120.74–148.18 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for blueplanet 110 TL3 M1 WM OD IIKX
Panel ClassRecommended QtyDC Array / Ratio
400W302–370 panels120.8–148.0 kW DC
440W274–337 panels120.6–148.3 kW DC
550W220–269 panels121.0–147.9 kW DC

CEC-Listed 240V Equivalents to KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (109.765 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Compatible Solar Panels for KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V19–23 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V19–23 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V19–22 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V20–23 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V20–23 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V15–18 per string (-10°C)Verify Pair

Engineering FAQ — KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX

What size circuit breaker does the KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX require under NEC 705.12?
At 109.765 kW continuous AC output on 480V (132A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the KACO new energy (Siemens) blueplanet 110 TL3 M1 WM OD IIKX?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 109.765 kW unit with 120.74 kW to 148.18 kW DC of solar modules without exceeding 1300V cold Voc.

More KACO new energy (Siemens) Inverters

blueplanet 150 TL3 M1 WM OD IIQ0 (151.228 kW)blueplanet 150 TL3 M1 WM OD IIQX (151.228 kW)blueplanet 110 TL3 M1 WM OD IIK0 (109.765 kW)blueplanet 125 TL3 M1 WM OD IIP0 (138.663 kW)blueplanet 125 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 137 TL3 M1 WM OD IIP0 (138.663 kW)All KACO new energy (Siemens) Equipment →