KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0 (151.228 kW)

150 kVA, 480 Vac, 1500Vdc Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
151.228 kW
CEC Weighted Eff.
99%
MPPT / Max DC
960–1300V / 1300V
NEC 705.12 Breaker
175A @ 660V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0 — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 960–1300 Vdc 960V 1300V MAX 1300V PV DC INPUT ≤ 1300V DC 151.228 kW · 99% CEC GRID-SUPPORT INVERTER AC OUTPUT 660V · 175A BRKR

Electrical & Grid-Support Datasheet

KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0 Electrical and Grid-Support Specifications
ManufacturerKACO new energy (Siemens)
Model Number (MPN)blueplanet 150 TL3 M1 WM OD IIQ0
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)151.228 kW (151,228 W)
Nominal DC Input (Pdco)153,101 W
Nominal AC Voltage660 Vac (3-Phase)
CEC Weighted Efficiency99%
MPPT Operating Window960 – 1300 Vdc (NREL SAM Measured)
Max DC Input Voltage1300 Vdc
Max DC Input Current146.5 A
Night Tare Loss5.25 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for blueplanet 150 TL3 M1 WM OD IIQ0
Max Continuous AC Current132.3 A @ 660V
125% Continuous Duty Current165.4 A
Minimum Standard Breaker175 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (166.35–204.16 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for blueplanet 150 TL3 M1 WM OD IIQ0
Panel ClassRecommended QtyDC Array / Ratio
400W416–510 panels166.4–204.0 kW DC
440W378–464 panels166.3–204.2 kW DC
550W302–371 panels166.1–204.1 kW DC

CEC-Listed 240V Equivalents to KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (151.228 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Engineering FAQ — KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0

What size circuit breaker does the KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0 require under NEC 705.12?
At 151.228 kW continuous AC output on 660V (132.3A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQ0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 151.228 kW unit with 166.35 kW to 204.16 kW DC of solar modules without exceeding 1300V cold Voc.

More KACO new energy (Siemens) Inverters

blueplanet 125 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 137 TL3 M1 WM OD IIP0 (138.663 kW)blueplanet 137 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 150 TL3 M1 WM OD IIQX (151.228 kW)blueplanet 110 TL3 M1 WM OD IIK0 (109.765 kW)blueplanet 110 TL3 M1 WM OD IIKX (109.765 kW)All KACO new energy (Siemens) Equipment →