KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0 (138.663 kW)
137 kVA, 480 Vac, 1500Vdc Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
138.663 kW
CEC Weighted Eff.
99%
MPPT / Max DC
875–1300V / 1300V
NEC 705.12 Breaker
175A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | KACO new energy (Siemens) |
|---|---|
| Model Number (MPN) | blueplanet 137 TL3 M1 WM OD IIP0 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 138.663 kW (138,663 W) |
| Nominal DC Input (Pdco) | 140,510 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 99% |
| MPPT Operating Window | 875 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 143.2 A |
| Night Tare Loss | 5.57 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 133.4 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 166.8 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (152.53–187.2 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 381–468 panels | 152.4–187.2 kW DC |
| 440W | 347–425 panels | 152.7–187.0 kW DC |
| 550W | 277–340 panels | 152.3–187.0 kW DC |
CEC-Listed 240V Equivalents to KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (138.663 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-510-BTB-HV | 510 W | 44.38 V | 27–27 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 33–34 per string (-10°C) | Verify Pair |
| REC Solar REC450AA 72 | 450 W | 53.2 V | 22–22 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM-R | 435 W | 40.7 V | 29–29 per string (-10°C) | Verify Pair |
Engineering FAQ — KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0
What size circuit breaker does the KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0 require under NEC 705.12?
At 138.663 kW continuous AC output on 600V (133.4A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the KACO new energy (Siemens) blueplanet 137 TL3 M1 WM OD IIP0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 138.663 kW unit with 152.53 kW to 187.2 kW DC of solar modules without exceeding 1300V cold Voc.
More KACO new energy (Siemens) Inverters
blueplanet 110 TL3 M1 WM OD IIKX (109.765 kW)blueplanet 125 TL3 M1 WM OD IIP0 (138.663 kW)blueplanet 125 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 137 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 150 TL3 M1 WM OD IIQ0 (151.228 kW)blueplanet 150 TL3 M1 WM OD IIQX (151.228 kW)All KACO new energy (Siemens) Equipment →