KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQX (151.228 kW)
150 kVA, 480 Vac, 1500Vdc Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
151.228 kW
CEC Weighted Eff.
99%
MPPT / Max DC
960–1300V / 1300V
NEC 705.12 Breaker
175A @ 660V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | KACO new energy (Siemens) |
|---|---|
| Model Number (MPN) | blueplanet 150 TL3 M1 WM OD IIQX |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 151.228 kW (151,228 W) |
| Nominal DC Input (Pdco) | 153,101 W |
| Nominal AC Voltage | 660 Vac (3-Phase) |
| CEC Weighted Efficiency | 99% |
| MPPT Operating Window | 960 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 146.5 A |
| Night Tare Loss | 5.25 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 132.3 A @ 660V |
|---|---|
| 125% Continuous Duty Current | 165.4 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (166.35–204.16 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 416–510 panels | 166.4–204.0 kW DC |
| 440W | 378–464 panels | 166.3–204.2 kW DC |
| 550W | 302–371 panels | 166.1–204.1 kW DC |
CEC-Listed 240V Equivalents to KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQX
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (151.228 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQX
What size circuit breaker does the KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQX require under NEC 705.12?
At 151.228 kW continuous AC output on 660V (132.3A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the KACO new energy (Siemens) blueplanet 150 TL3 M1 WM OD IIQX?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 151.228 kW unit with 166.35 kW to 204.16 kW DC of solar modules without exceeding 1300V cold Voc.
More KACO new energy (Siemens) Inverters
blueplanet 137 TL3 M1 WM OD IIP0 (138.663 kW)blueplanet 137 TL3 M1 WM OD IIPX (138.663 kW)blueplanet 150 TL3 M1 WM OD IIQ0 (151.228 kW)blueplanet 110 TL3 M1 WM OD IIK0 (109.765 kW)blueplanet 110 TL3 M1 WM OD IIKX (109.765 kW)blueplanet 125 TL3 M1 WM OD IIP0 (138.663 kW)All KACO new energy (Siemens) Equipment →