Power Center Max Hybrid 30 (208V) (30.025 kW)
30 kW, 120 Vac Grid Support Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
30.025 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
270–500V / 500V
NEC 705.12 Breaker
200A @ 120V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Center |
|---|---|
| Model Number (MPN) | Max Hybrid 30 (208V) |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 30.025 kW (30,025 W) |
| Nominal DC Input (Pdco) | 31,420 W |
| Nominal AC Voltage | 120 Vac (3-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 270 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 500 Vdc |
| Max DC Input Current | 81.6 A |
| Night Tare Loss | 31.9 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | TUV Rheinland of North America |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 144.5 A @ 120V |
|---|---|
| 125% Continuous Duty Current | 180.6 A |
| Minimum Standard Breaker | 200 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (33.03–40.53 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 83–101 panels | 33.2–40.4 kW DC |
| 440W | 75–92 panels | 33.0–40.5 kW DC |
| 550W | 60–74 panels | 33.0–40.7 kW DC |
CEC-Listed 240V Equivalents to Power Center Max Hybrid 30 (208V)
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (30.025 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Power Center Max Hybrid 30 (208V)
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 8–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 8–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–7 per string (-10°C) | Verify Pair |
Engineering FAQ — Power Center Max Hybrid 30 (208V)
What size circuit breaker does the Power Center Max Hybrid 30 (208V) require under NEC 705.12?
At 30.025 kW continuous AC output on 120V (144.5A continuous), the 125% continuous duty rule requires a minimum 200A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Center Max Hybrid 30 (208V)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 30.025 kW unit with 33.03 kW to 40.53 kW DC of solar modules without exceeding 500V cold Voc.