60 kW, 277 Vac Grid Support Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
60.05 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
540–850V / 850V
NEC 705.12 Breaker
175A @ 277V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Center |
|---|---|
| Model Number (MPN) | Max Hybrid 60 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 60.05 kW (60,050 W) |
| Nominal DC Input (Pdco) | 61,997 W |
| Nominal AC Voltage | 277 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 540 – 850 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 850 Vdc |
| Max DC Input Current | 89.2 A |
| Night Tare Loss | 5.29 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | TUV Rheinland |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 125.2 A @ 277V |
|---|---|
| 125% Continuous Duty Current | 156.5 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (66.06–81.07 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 165–203 panels | 66.0–81.2 kW DC |
| 440W | 150–184 panels | 66.0–81.0 kW DC |
| 550W | 120–147 panels | 66.0–80.8 kW DC |
CEC-Listed 240V Equivalents to Power Center Max Hybrid 60
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (60.05 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Power Center Max Hybrid 60
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 15–15 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 15–15 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 15–15 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 15–15 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 21–21 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | 19–19 per string (-10°C) | Verify Pair |
Engineering FAQ — Power Center Max Hybrid 60
What size circuit breaker does the Power Center Max Hybrid 60 require under NEC 705.12?
At 60.05 kW continuous AC output on 277V (125.2A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Center Max Hybrid 60?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 60.05 kW unit with 66.06 kW to 81.07 kW DC of solar modules without exceeding 850V cold Voc.