SMA Solar official logoCEC-Listed · Commercial / C&IStringUL 1741-SB (3rd Ed.)

SMA Solar STP 13-US-50 (13 kW)

13 kW, 208 Vac, 3-phase, transformerless, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
13 kW
CEC Weighted Eff.
97%
MPPT / Max DC
230–640V / 640V
NEC 705.12 Breaker
50A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
SMA Solar STP 13-US-50 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 230–640 Vdc 230V 640V MAX 640V PV DC INPUT ≤ 640V DC 13 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 208V · 50A BRKR

Electrical & Grid-Support Datasheet

SMA Solar STP 13-US-50 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)STP 13-US-50
Inverter TopologyString Inverter
Continuous AC Power (Paco)13 kW (13,000 W)
Nominal DC Input (Pdco)13,553 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window230 – 640 Vdc (NREL SAM Measured)
Max DC Input Voltage640 Vdc
Max DC Input Current40.5 A
Night Tare Loss4.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for STP 13-US-50
Max Continuous AC Current36.1 A @ 208V
125% Continuous Duty Current45.1 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (14.3–17.55 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for STP 13-US-50
Panel ClassRecommended QtyDC Array / Ratio
400W36–44 panels14.4–17.6 kW DC
440W33–40 panels14.5–17.6 kW DC
550W26–32 panels14.3–17.6 kW DC

CEC-Listed 240V Equivalents to SMA Solar STP 13-US-50

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (13 kW String Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V12.5 kW
Fronius · String

Primo 12.5-1 208-240

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V11.397 kW
GoodWe · String

GEP11.4-1-US30

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V11.39 kW
SolarEdge · String

SE11400A-US

CEC Efficiency: 97.5%
Datasheet →

Compatible Solar Panels for SMA Solar STP 13-US-50

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar STP 13-US-50
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–11 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–11 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–11 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–9 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar STP 13-US-50

What size circuit breaker does the SMA Solar STP 13-US-50 require under NEC 705.12?
At 13 kW continuous AC output on 208V (36.1A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SMA Solar STP 13-US-50?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 13 kW unit with 14.3 kW to 17.55 kW DC of solar modules without exceeding 640V cold Voc.

More SMA Solar Inverters

SB7.7-1SP-US-40 (7.68 kW)SBSE9.6-US-50 (9.569 kW)SBSE11.5-US-50 (11.483 kW)SB3.0-1SP-US-40 (3 kW)SB3.8-1SP-US-40 (3.8 kW)SBS3.8-US-10 (3.8 kW)All SMA Solar Equipment →