SolarEdge SE120KUS (40.252 kW)
120 kW, 480 Vac, 3-phase Grid Support Utility Interactive Inverter. (Made up of three SE40KUS installed together rated max output power = 120kW). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
40.252 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
790–950V / 950V
NEC 705.12 Breaker
70A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SolarEdge |
|---|---|
| Model Number (MPN) | SE120KUS |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 40.252 kW (40,252 W) |
| Nominal DC Input (Pdco) | 41,001 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 790 – 950 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 950 Vdc |
| Max DC Input Current | 48.2 A |
| Night Tare Loss | 7.43 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 48.4 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 60.5 A |
| Minimum Standard Breaker | 70 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (44.28–54.34 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 111–136 panels | 44.4–54.4 kW DC |
| 440W | 101–124 panels | 44.4–54.6 kW DC |
| 550W | 81–99 panels | 44.5–54.5 kW DC |
CEC-Listed 240V Equivalents to SolarEdge SE120KUS
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (40.252 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — SolarEdge SE120KUS
What size circuit breaker does the SolarEdge SE120KUS require under NEC 705.12?
At 40.252 kW continuous AC output on 480V (48.4A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE120KUS?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 40.252 kW unit with 44.28 kW to 54.34 kW DC of solar modules without exceeding 950V cold Voc.