SolarEdge SE285KUS (284.159 kW)
285 kW, 600 Vac, 3-phase, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
284.159 kW
CEC Weighted Eff.
99%
MPPT / Max DC
1090–1320V / 1320V
NEC 705.12 Breaker
350A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SolarEdge |
|---|---|
| Model Number (MPN) | SE285KUS |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 284.159 kW (284,159 W) |
| Nominal DC Input (Pdco) | 288,163 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 99% |
| MPPT Operating Window | 1090 – 1320 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1320 Vdc |
| Max DC Input Current | 230.5 A |
| Night Tare Loss | 21.6 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 273.4 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 341.8 A |
| Minimum Standard Breaker | 350 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (312.57–383.61 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 781–959 panels | 312.4–383.6 kW DC |
| 440W | 710–872 panels | 312.4–383.7 kW DC |
| 550W | 568–697 panels | 312.4–383.4 kW DC |
CEC-Listed 240V Equivalents to SolarEdge SE285KUS
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (284.159 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — SolarEdge SE285KUS
What size circuit breaker does the SolarEdge SE285KUS require under NEC 705.12?
At 284.159 kW continuous AC output on 600V (273.4A continuous), the 125% continuous duty rule requires a minimum 350A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the SolarEdge SE285KUS?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 284.159 kW unit with 312.57 kW to 383.61 kW DC of solar modules without exceeding 1320V cold Voc.