Hyundai Energy official logoCEC-Listed · ResidentialUL 61730

Hyundai Energy HiS-T615NJ

615W, 156 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
615W / 581.4W
Efficiency
22.28%
Voc / Vmp
56.74V / 46.9V
Max String (600V)
9 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Hyundai Energy HiS-T615NJ — Illustrative category photo — not this exact model · Real commercial solar module installation
Illustrative category photo — not this exact model · Real commercial solar module installationWikimedia Commons — File:Dornbirn-Rhombergs Fabrik-photovoltaic systems-01ASD.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (156 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 61.37V Isc 13.67A MPP 615W (46.9V · 13.12A) Voc 56.74V DC Voltage (V) · Efficiency 22.28%

Electrical & Thermal Specifications (STC)

Hyundai Energy HiS-T615NJ Electrical and Mechanical Specifications
ManufacturerHyundai Energy
Model Number (MPN)HiS-T615NJ
Cell TechnologyMono-c-Si · 156 cells
Nameplate Power (Pmax STC)615 W
Real-World Output (PTC)581.4 W (94.5% of STC)
Module Efficiency22.28% (222.8 W/m²)
Open-Circuit Voltage (Voc)56.74 V
Maximum Power Voltage (Vmp)46.9 V
Short-Circuit Current (Isc)13.67 A (NEC 1.25× = 17.09 A)
Maximum Power Current (Imp)13.12 A
Temp. Coeff. Power (γPmax)-0.294 %/°C
Temp. Coeff. Voltage (βVoc)-0.233 %/°C
Temp. Coeff. Current (αIsc)+0.03 %/°C
Nominal Cell Temp (NOCT)45.1 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.76 m² (29.7 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.233%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for HiS-T615NJ
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
56.74 V1017
0°C / 32°F
Freezing / Mild Winter
60.05 V916
-10°C / 14°F
TX / Southeast / Mid-Atlantic
61.37 V916
-20°C / -4°F
Northeast / Midwest Winter
62.69 V915
-30°C / -22°F
Northern Plains / Mountain
64.01 V915

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using HiS-T615NJ
Target SizePanels NeededActual DCRoof Footprint
6 kW10 panels6.15 kW297 sq ft (27.6 m²)
8 kW14 panels8.61 kW416 sq ft (38.6 m²)
10 kW17 panels10.46 kW505 sq ft (46.9 m²)
12 kW20 panels12.30 kW594 sq ft (55.2 m²)

Compatible CEC-Listed Inverters for HiS-T615NJ

Open full string calculator with this panel →
Compatible US-Certified Inverters for Hyundai Energy HiS-T615NJ
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–9 panels/string at -10°CVerify Pair
Enphase Energy IQ8D-BATMicroinverter0.639 kW97%1:1 micro pairing (0.96 DC/AC ratio)Verify Pair
Fronius Primo 3.8-1 208-240String3.8 kW95.5%3–13 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%3–8 panels/string at -10°CVerify Pair
Growatt MIN 6000TL-XH-USHybrid5.918 kW97%5–7 panels/string at -10°CVerify Pair
Growatt MIN 7600TL-XH2 USHybrid7.651 kW96%4–8 panels/string at -10°CVerify Pair

Other Power Classes in This Hyundai Energy Series (7 total CEC variants)

Sibling Power Classes in the Hyundai Energy Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
HiS-T620NJ620 W586.2 W56.95 V13.75 A22.46%
HiS-T625NJ625 W591 W57.15 V13.82 A22.64%
HiS-T630NJ630 W595.9 W57.36 V13.9 A22.83%
HiS-T635NJ635 W600.7 W57.56 V13.98 A23.01%
HiS-T640NJ640 W605.6 W57.77 V14.06 A23.19%
HiS-T645NJ645 W610.4 W57.97 V14.14 A23.37%

Engineering FAQ — Hyundai Energy HiS-T615NJ

How many Hyundai Energy HiS-T615NJ panels can fit in one 600V string?
At -10°C (14°F) ambient, the HiS-T615NJ open-circuit voltage rises from 56.74V to 61.37V (using βVoc -0.233%/°C), allowing up to 9 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hyundai Energy HiS-T615NJ?
Rated at 615W STC, the HiS-T615NJ carries a 581.4W PTC rating (94.5% PTC/STC ratio) and 22.28% module efficiency across 2.76 m² (29.7 sq ft).
Is the Hyundai Energy HiS-T615NJ listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Hyundai Energy Solar Panels

HiN-T650NJ (650W)HiS-T645NJ (645W)HiN-T630NJ (630W)HiN-T600NI (600W)HiN-T590NI (590W)HiN-T450NF(BK) (450W)All Hyundai Energy Equipment →