Fortress Power FP-Envy Duo 21 (16.153 kW)
16 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
16.153 kW
CEC Weighted Eff.
97%
MPPT / Max DC
250–440V / 440V
NEC 705.12 Breaker
90A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Fortress Power |
|---|---|
| Model Number (MPN) | FP-Envy Duo 21 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 16.153 kW (16,153 W) |
| Nominal DC Input (Pdco) | 16,720 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 250 – 440 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 440 Vdc |
| Max DC Input Current | 46.4 A |
| Night Tare Loss | 29.36 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 67.3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 84.1 A |
| Minimum Standard Breaker | 90 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (17.77–21.81 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 44–55 panels | 17.6–22.0 kW DC |
| 440W | 40–50 panels | 17.6–22.0 kW DC |
| 550W | 32–40 panels | 17.6–22.0 kW DC |
Compatible Solar Panels for Fortress Power FP-Envy Duo 21
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–7 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–8 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–6 per string (-10°C) | Verify Pair |
Engineering FAQ — Fortress Power FP-Envy Duo 21
What size circuit breaker does the Fortress Power FP-Envy Duo 21 require under NEC 705.12?
At 16.153 kW continuous AC output on 240V (67.3A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Fortress Power FP-Envy Duo 21?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 16.153 kW unit with 17.77 kW to 21.81 kW DC of solar modules without exceeding 440V cold Voc.