FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fortress Power FP-Envy Duo 21 (16.153 kW)

16 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
16.153 kW
CEC Weighted Eff.
97%
MPPT / Max DC
250–440V / 440V
NEC 705.12 Breaker
90A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power FP-Envy Duo 21 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–440 Vdc 250V 440V MAX 440V PV DC INPUT ≤ 440V DC 16.153 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 90A BRKR

Electrical & Grid-Support Datasheet

Fortress Power FP-Envy Duo 21 Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)FP-Envy Duo 21
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)16.153 kW (16,153 W)
Nominal DC Input (Pdco)16,720 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window250 – 440 Vdc (NREL SAM Measured)
Max DC Input Voltage440 Vdc
Max DC Input Current46.4 A
Night Tare Loss29.36 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for FP-Envy Duo 21
Max Continuous AC Current67.3 A @ 240V
125% Continuous Duty Current84.1 A
Minimum Standard Breaker90 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (17.77–21.81 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for FP-Envy Duo 21
Panel ClassRecommended QtyDC Array / Ratio
400W44–55 panels17.6–22.0 kW DC
440W40–50 panels17.6–22.0 kW DC
550W32–40 panels17.6–22.0 kW DC

Compatible Solar Panels for Fortress Power FP-Envy Duo 21

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fortress Power FP-Envy Duo 21
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power FP-Envy Duo 21

What size circuit breaker does the Fortress Power FP-Envy Duo 21 require under NEC 705.12?
At 16.153 kW continuous AC output on 240V (67.3A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Fortress Power FP-Envy Duo 21?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 16.153 kW unit with 17.77 kW to 21.81 kW DC of solar modules without exceeding 440V cold Voc.

More Fortress Power Inverters

EdgeOn Duo 15 Pro (11.567 kW)FP-ENVY-12K (11.933 kW)FP-Envy 15K (16.153 kW)Avalon HV PC50 (5.002 kW)EdgeOn Duo 7.5 (5.04 kW)EdgeOn Duo 9 (6.149 kW)All Fortress Power Equipment →