OB CEC-Listed · Commercial / C&ICommercial 3-Phase

OutBack Power PHXL480-10k (9.975 kW)

10 kW, 480 Vac, 3 phase Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.975 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
450–850V / 850V
NEC 705.12 Breaker
15A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
OutBack Power PHXL480-10k — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 450–850 Vdc 450V 850V MAX 850V PV DC INPUT ≤ 850V DC 9.975 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 480V · 15A BRKR

Electrical & Grid-Support Datasheet

OutBack Power PHXL480-10k Electrical and Grid-Support Specifications
ManufacturerOutBack Power
Model Number (MPN)PHXL480-10k
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)9.975 kW (9,975 W)
Nominal DC Input (Pdco)10,172 W
Nominal AC Voltage480 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window450 – 850 Vdc (NREL SAM Measured)
Max DC Input Voltage850 Vdc
Max DC Input Current13.6 A
Night Tare Loss8.3 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for PHXL480-10k
Max Continuous AC Current12 A @ 480V
125% Continuous Duty Current15.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.97–13.47 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for PHXL480-10k
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–24 panels11.0–13.2 kW DC

CEC-Listed 240V Equivalents to OutBack Power PHXL480-10k

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (9.975 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V9.995 kW
Fronius · String

Primo 10.0-1 208-240

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V10 kW
Solis (Ginlong) · String

1P10K-4G-US

CEC Efficiency: 97.5%
Datasheet →
CEC-Listed · 240V9.94 kW
SolarEdge · String

SE10000A-US

CEC Efficiency: 97.5%
Datasheet →

Compatible Solar Panels for OutBack Power PHXL480-10k

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for OutBack Power PHXL480-10k
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V12–15 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V12–15 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V12–14 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V13–15 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V13–15 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V10–11 per string (-10°C)Verify Pair

Engineering FAQ — OutBack Power PHXL480-10k

What size circuit breaker does the OutBack Power PHXL480-10k require under NEC 705.12?
At 9.975 kW continuous AC output on 480V (12A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the OutBack Power PHXL480-10k?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.975 kW unit with 10.97 kW to 13.47 kW DC of solar modules without exceeding 850V cold Voc.

More OutBack Power Inverters

SBX5048-120/240 (4.985 kW)GS8048A (7.2 kW)OGHI8048A (7.638 kW)GS4048A (3.6 kW)All OutBack Power Equipment →