Power Center D350-M1A-208A (0.303 kW)
350 VA, 208 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.303 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Center |
|---|---|
| Model Number (MPN) | D350-M1A-208A |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.303 kW (303 W) |
| Nominal DC Input (Pdco) | 315 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 22 – 55 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 55 Vdc |
| Max DC Input Current | 9 A |
| Night Tare Loss | 0.2 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 0.8 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 1.0 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.33–0.41 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.32× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.45× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.82× DC/AC) |
CEC-Listed 240V Equivalents to Power Center D350-M1A-208A
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.303 kW Microinverter) and can be added directly to your US System Kit:
CEC-Listed · 240V0.29 kW
Qcells (Hanwha) · Microinverter
Q.PEAK DUO BLK-G10+/AC 360
CEC Efficiency: 97%
Compatible Solar Panels for Power Center D350-M1A-208A
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | DC/AC 1.57 (1 panel/input) | Verify Pair |
| SEG Solar SEG-465-BTE-BG | 465 W | 36.4 V | DC/AC 1.53 (1 panel/input) | Verify Pair |
| Mission Solar MSX10-460HN0B {C} | 460 W | 39.3 V | DC/AC 1.52 (1 panel/input) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | DC/AC 1.52 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | DC/AC 1.47 (1 panel/input) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | DC/AC 1.52 (1 panel/input) | Verify Pair |
Engineering FAQ — Power Center D350-M1A-208A
What size circuit breaker does the Power Center D350-M1A-208A require under NEC 705.12?
At 0.303 kW continuous AC output on 208V (0.8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Power Center D350-M1A-208A?
As a 303W microinverter, it pairs 1:1 with panels rated roughly 318W to 439W STC.