SolarEdge official logoCEC-Listed · Commercial / C&IStringUL 1741-SB (3rd Ed.)

SolarEdge SE43.2KUS (14.51 kW)

43.2 kW, 208 Vac, 3-phase Grid Support Utility Interactive Inverter. (Made up of three SE14.4KUS installed together rated max output power = 43.2kW). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
14.51 kW
CEC Weighted Eff.
97%
MPPT / Max DC
400–600V / 600V
NEC 705.12 Breaker
60A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
SolarEdge SE43.2KUS — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 400–600 Vdc 400V 600V MAX 600V PV DC INPUT ≤ 600V DC 14.51 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 208V · 60A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE43.2KUS Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE43.2KUS
Inverter TopologyString Inverter
Continuous AC Power (Paco)14.51 kW (14,510 W)
Nominal DC Input (Pdco)15,020 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window400 – 600 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current32.7 A
Night Tare Loss4.16 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE43.2KUS
Max Continuous AC Current40.3 A @ 208V
125% Continuous Duty Current50.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (15.96–19.59 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE43.2KUS
Panel ClassRecommended QtyDC Array / Ratio
400W40–49 panels16.0–19.6 kW DC
440W36–45 panels15.8–19.8 kW DC
550W29–36 panels15.9–19.8 kW DC

CEC-Listed 240V Equivalents to SolarEdge SE43.2KUS

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (14.51 kW String Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V15 kW
Fronius · String

Primo 15.0-1 208-240

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V14.72 kW
SRNE Solar · Hybrid

HEBP48150U320-H

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V14.79 kW
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) · Hybrid

InfiniSolar WP LV 15KW

CEC Efficiency: 97%
Datasheet →

Compatible Solar Panels for SolarEdge SE43.2KUS

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SolarEdge SE43.2KUS
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
SEG Solar SEG-450-BTD-BG450 W39.6 V14–14 per string (-10°C)Verify Pair
Canadian Solar CS6.2-48TM-430H430 W35 V16–16 per string (-10°C)Verify Pair
REC Solar REC430AA Pure 2430 W49 V11–11 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.TRON BLK-G1+ 395395 W41.51 V13–13 per string (-10°C)Verify Pair
Silfab Solar SIL-440QD440 W38.97 V14–14 per string (-10°C)Verify Pair

Engineering FAQ — SolarEdge SE43.2KUS

What size circuit breaker does the SolarEdge SE43.2KUS require under NEC 705.12?
At 14.51 kW continuous AC output on 208V (40.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE43.2KUS?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 14.51 kW unit with 15.96 kW to 19.59 kW DC of solar modules without exceeding 600V cold Voc.

More SolarEdge Inverters

SE11400H-US (11.393 kW)NX11500T-US (11.52 kW)NX13000T-US (13 kW)SE3000H-US (2.962 kW)SE3000x (3.01 kW)SE3300x (3.251 kW)All SolarEdge Equipment →