NEP (Northern Electric & Power) BDM-300-208A (0.255 kW)
300 VA, 208 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.255 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | NEP (Northern Electric & Power) |
|---|---|
| Model Number (MPN) | BDM-300-208A |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.255 kW (255 W) |
| Nominal DC Input (Pdco) | 264 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 22 – 55 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 55 Vdc |
| Max DC Input Current | 7.6 A |
| Night Tare Loss | 1.2 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 0.7 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 0.9 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.28–0.34 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.57× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.73× DC/AC) |
| 550W | 1 panel | 1:1 pairing (2.16× DC/AC) |
CEC-Listed 240V Equivalents to NEP (Northern Electric & Power) BDM-300-208A
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.255 kW Microinverter) and can be added directly to your US System Kit:
CEC-Listed · 240V0.289 kW
Chilicon Power (Generac) · Microinverter
CP-250E-60/72-208/240-MC4
CEC Efficiency: 96%
CEC-Listed · 240V0.289 kW
NEP (Northern Electric & Power) · Microinverter
BDM-300-240A
CEC Efficiency: 96.5%
Compatible Solar Panels for NEP (Northern Electric & Power) BDM-300-208A
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395 | 395 W | 45.27 V | DC/AC 1.55 (1 panel/input) | Verify Pair |
| REC Solar REC405TP3SM 72 XV | 405 W | 48.6 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| Maxeon / SunPower SPR-MAX6-400-BLK | 400 W | 48.1 V | DC/AC 1.57 (1 panel/input) | Verify Pair |
| JinkoSolar JKM405N-54HL4R-B | 405 W | 38.1 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| Silfab Solar SIL-400QD | 400 W | 38.71 V | DC/AC 1.57 (1 panel/input) | Verify Pair |
| Trina Solar TSM-395NE09RC.05 | 395 W | 48.8 V | DC/AC 1.55 (1 panel/input) | Verify Pair |
Engineering FAQ — NEP (Northern Electric & Power) BDM-300-208A
What size circuit breaker does the NEP (Northern Electric & Power) BDM-300-208A require under NEC 705.12?
At 0.255 kW continuous AC output on 208V (0.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the NEP (Northern Electric & Power) BDM-300-208A?
As a 255W microinverter, it pairs 1:1 with panels rated roughly 268W to 370W STC.